Save yourself the trouble of putting together a configuration! The starter kits are available in 3 versions, suitable for most HPLC applications. Price advantage compared to buying single Safety Caps - significantly cheaper. Request your individual offer! Use our new configurator to narrow down the selection:
Configurator
Filter products
Frequently asked questions about equipping HPLC systems with Safety Caps
Which components are part of a complete Safety Cap system?
A complete system consists of: Eluent bottle; HPLC Safety Cap with media-contacting core; Supply capillaries; Suitable fittings; Blind plugs; Vent valve; Inlet filters; Clear identification of the eluent paths Only when these components are technically coordinated can the solvent supply operate as a controlled closed and reproducible system.
Which criteria are used to select an HPLC Safety Cap?
Important selection criteria include: Analytical or preparative application; Isocratic or gradient method; Number of eluent bottles; Bottle material and bottle thread; Number of supply capillaries; Capillary outside and inside diameters; Required flow rate; Eluents and additives used; PFAS sensitivity of the application; Possible future extensions The application determines the Safety Cap configuration – not the other way round.
Which Safety Cap size do I need?
The size depends on the maximum number of supply capillaries required. Typical variants are: Safety Cap I: one port; Safety Cap II: two ports; Safety Cap III: three ports; Safety Cap IV: four ports; Safety Cap VI: six ports Unused ports must be closed with suitable blind plugs.
Why are several fitting sizes supplied with a Safety Cap?
For analytical Safety Caps, SCAT supplies fittings for the common capillary outside diameters of 1.6 mm, 2.3 mm and 3.2 mm for each capillary port. This allows the appropriate fitting to be selected during installation. The Safety Cap does not have to be specified for a single capillary size when ordering.
What are blind plugs used for?
An open port creates a direct connection between the eluent bottle and the laboratory environment. This can allow solvent vapours to escape while air, moisture and contaminants can enter the bottle. At the same time, the composition of volatile eluent mixtures may change. The following therefore applies to standard capillary ports: occupied ports are sealed with the appropriate fitting, while unused ports are closed with a blind plug.
How is an HPLC Safety Cap installed correctly?
Installation is carried out in the following steps: 1. Determine the capillary outside diameter. 2. Select the appropriate fitting. 3. Feed the capillary through the fitting and Safety Cap. 4. Install the inlet filter. 5. Set the insertion depth. 6. Secure the capillary with the fitting. 7. Close unused ports with blind plugs. 8. Insert the vent valve. 9. Screw the Safety Cap onto the eluent bottle. 10. Fill and vent the line and prime the pump in accordance with the manufacturer's instructions.
Which components must be checked or replaced regularly?
Capillaries, fittings, blind plugs, inlet filters, the vent valve, identification and all connections should be checked regularly. Vent valves have a preventive replacement interval of six months. Other components are replaced if they are damaged, contaminated, deformed or malfunctioning.
Why must a vent valve be replaced after six months?
SCAT specifies a service life of six months for standard and GreenLine vent valves. After this period, the complete valve is replaced preventively, even if no visible changes can be detected. Earlier replacement is required if the valve is damaged, heavily contaminated, wetted or flooded with eluent, or if pressure equalisation no longer functions reliably. The replacement date should be documented directly on the valve or in the maintenance plan.